QCID Ventilated Odor Control System

Specifications

Floor Mounted Chamber Unit

  • Height:62" plus horizontal inlet size
  • Width & Depth:1.6 sq. ft./1000 cfm
  • Static Pressure Loss:0.40" to 0.60"
  • Velocity in Chamber:800 to 900 fpm
  • Shipping Weight:500 to 1400 lbs.
  • Operating Weight:520 to 1440 lbs.
  • Fan Motor Size:1/2 to 5 hp

Number of 1.3 gph Nozzles

  • 1000 to 2500 cfm:2 nozzles
  • 2600 to 5000 cfm:4 nozzles
  • 5100 to 8000 cfm:9 nozzles

Utilities

  • Fan Electrical 1/2 hp:20V, 1, 60 hz, 10 amp
  • 1-1/2 to 2 hp:220V, 1, 60 hz, 10-15 amp
  • 3 to 5 hp:460V, 3, 60 hz, 6-12 amp
  • Feed System Water:4 gpm, 45 psi, Potable
  • Drain:Sanitary Floor Drain

Operating Costs

  • Chemical Costs/cfm/year:$0.50 to $1.00
  • Fan Electrical Usage 1/2 hp:1.03 kw/h
  • 1-1/2 to 2 hp:1.89 to 2.84 kw/h
  • 3 to 5 hp:4.10 to 8.21 kw/h

Applications - 1,000 to 8,000 cfm

Municipal Wastewater Sites

  • Enclosed Headworks Areas
  • Enclosed Lift Station Wet Wells
  • Enclosed Sludge Dewatering Areas
  • Enclosed Sludge Storage Areas
  • Enclosed Grit and Screening Areas

Industrial Sites

  • Enclosed Solid Waste Receiving Areas
  • Enclosed Solid Waste Processing Areas
  • Industrial Exhaust Systems

Companion Chemical Feed System

  • Mist Pro Chemical Feed and Dilution System
  • Series 950 Chemical Feed and Dilution System
QCID System

System Overview

The QCID system provides both ventilation and odor control for point source areas. QCID, which stands for "Quick-Contact-In-Duct" features a contact time of 0.3 seconds. The system has the smallest footprint of any comparably sized odor control system and is an excellent choice when space is limited. This system is designed to use NuTech's Chi-X or DeAmine Odor Eliminators. The targeted odors are oxidized organic odors for applications with fairly consistent odor loading.

Seasonal variation in ventilation requirements is accommodated by the use of a two-speed or variable speed fan motor. Fabricated from stainless steel, the QCID system can be supplied in sizes from 1,000 to 8,000 cfm for situations where the total static pressure requirement is 3.5" or less. Custom designed, the QCID is built to handle any needed air inlet and outlet configuration. Systems are typically floor mounted, however; mounting options are available to fit the site. Installation costs average 10 to 20% of the capital costs.

With a QCID, NuTech guarantees odor reduction at the discharge stack to 200 odor units or less (D/T), with Butanol intensity of 3 or less. Butanol intensities as low as 1 are possible. Effectiveness on hydrogen sulfide is limited to 1 ppm. If H2S levels exceed one ppm, companion treatment for H2S should be considered.